• <dt id="MfkQ6"></dt>
    1. <address></address>

          Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
          0517-86918678
          Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
          Tel:0517-86918678
          Fax:0517-86918679
          Email:zhongweick@https://czqccj.com
          Post Encoding:211600

          Frequency converter special cable

          變(bian)頻(pin)器專(zhuan)用電(dian)纜.jpg
          • 變(bian)頻(pin)器專(zhuan)用電纜.jpg
          Inverter dedicated cable is fit for ac rated voltage up to and including 0.6/1 kv frequency conversi…

          Description:

          An overview, cables:
          Inverter dedicated cable is fit for ac rated voltage up to and including 0.6/1 kv frequency conversion control system for power supply cable or electrical connections, the product has strong resistance to voltage impact, can withstand variable frequency pulse voltage, cable has good shielding electromagnetic interference, and effectively eliminate the noise of the frequency conversion motor, ensure the system stable operation.Widely used in metallurgy, electric power, petrochemical and other industries.
          Second, the frequency converter special cable standards:
          Q/CLB04-2003 
          Flame retardant fire-resistant characteristic test execution GB12666-90 standard
          Three, frequency converter special cable using features:
          1, ac rated voltage U0 / U 0.6/1 kv.
          The highest working temperature: silicone rubber insulated 180 ℃;
          Fluorine 46 insulation 200 ℃ and 260 ℃.
          PVC insulated 70 ℃;
          Crosslinked polyethylene 90 ℃;
          Minimum ambient temperature: cable when the ambient temperature under installation should not below - 40 ℃;PVC sheathed cable not below 0 ℃.
          2, cable installation temperature under installation should not below 25 ℃.
          Permissive bending radius, cable, cable minimum 10 times of cable diameter
          Four, allow temperature and working voltage:
          1, allows the conductor work continuously the highest temperature of 180 degrees Celsius.Short circuit when the highest temperature of 250 degrees Celsius.
          2, in the transport, storage, handling, radiation and a free bending when working + 5 ℃, or fixed installation - 10 ℃ or higher.
          3, rated voltage: 600/1000 v, ac test voltage 3500 v.
          Five, the frequency converter special cable product features:
          1, low effective capacitance.
          2, has shielding performance.
          3, good fireproof combustion performance, can be used in the dangerous area.
          4, low transmission impedance, contains the cable shielding layer, in order to prevent electromagnetic interference, transfer impedance RX is the shielding effectiveness of induced resistance and capacitance to measure, low transmission impedance can provide good electromagnetic compatibility.
          5, symmetrical three core design, electromagnetic compatibility, better than four core cable better performance.Three weather resistance and heat-resistant resin insulated wire core in aperture place even isometric twisted, forming a real concentric structure
          Six, frequency converter special cable main technical indicators:
          1.The finished cable conductor dc resistance (the prescribed GB3956)
          2.Finished cable insulation resistance (20 ℃) fluorine plastic and silicone rubber insulation shall be not less than 100 m Ω * km.PVC insulated should not be less than 50 M Ω * km.
          3.The finished cable communication through 50 hz3. 5 kv / 5 min is not breakdown voltage test.
          4.Shielding layer transfer impedance
          Cable in 100 MHZ transmission impedance is equal to or less than 100 Ω/m.
          The ideal of the cable shielding inhibition coefficient is equal to or less than 0.7.
          Seven, inverter dedicated cable basic type and name:

          model
          The name of the
          BPGG
          Silicone rubber insulated and sheathed wire braided shielding high-temperature frequency conversion power cable.
          BPGGP2
          Silicone rubber insulated and sheathed copper tape around the package block high temperature resistant frequency conversion power cable.
          BPGGPP2
          Silicone rubber insulated and sheathed wire braided copper tape around the package block high temperature resistant frequency conversion power cable.
          BPGGP3
          Silicone rubber insulated and sheathed aluminum polyester composite film around the package block high temperature resistant frequency conversion power cable.
          BPGVFP
          Silicone rubber insulated sheathed wire braided shielding high-temperature frequency conversion power cable.
          BPGVFP2
          Silicone rubber insulated sheathed copper tape around the package block high temperature resistant frequency conversion power cable.
          BPGVFPP2
          Silicone rubber insulated sheathed wire braided copper tape around the package block high temperature resistant frequency conversion power cable.
          BPGVFP3
          Silicone rubber insulating sheath aluminum polyester composite film around the package block high temperature resistant frequency conversion power cable.
          BPFFP
          Fluorine 46 insulated and sheathed wire braided shielding high-temperature frequency conversion power cable.
          BPFFP2
          Fluorine 46 insulated and sheathed copper tape around the package block high temperature resistant frequency conversion power cable.
          BPFFPP2
          Fluorine 46 insulated and sheathed wire braided copper tape around the package block high temperature resistant frequency conversion power cable
          BPFFP3
          46 insulation and sheath of aluminum fluoride polyester composite film around the package block high temperature resistant frequency conversion power cable.
          BPVVP
          PVC insulated and sheathed wire braided shielding frequency conversion power cable.
          BPVVP2
          PVC insulated and sheathed copper tape around the package block frequency conversion power cable.
          BPVVPP2
          PVC insulated and sheathed wire braided copper tape around the package block frequency conversion power cable.
          BPVVP3
          PVC insulated and sheathed aluminum polyester composite film around the package block frequency conversion power cable.
          BPYJVP
          Crosslinked polyethylene insulated PVC sheathed wire braided shielding frequency conversion power cable.
          BPYJVP2
          Cross-linked polyethylene insulated PVC sheathed copper tape around the package block frequency conversion power cable.
          BPYJVPP2
          Crosslinked polyethylene insulated PVC sheathed wire braided copper tape around the package block frequency conversion power cable.
          BPYJVP3
          Cross-linked polyethylene insulated PVC sheathed aluminum polyester composite film around the package block frequency conversion power cable.

          Note: copper wire in the conductor wire core can be used in a tin, flame retardant cable type before adding ZR, soft cable structure and R.
          Eight, code name and meaning:

          Code name
          Symbol meaning
          BP
          Frequency conversion power cable
          Copper conductor
          omit
          G
          Silicone rubber insulation or sheath
          F
          F46 insulation or sheath
          V
          PVC insulated and sheathed
          YJ
          Cross-linked polyethylene insulation
          VF
          sheath
          P(P1)
          Braided copper shield (tin braided shielding)
          P2
          Copper strip winding and shielding
          P3
          Aluminum polyester composite film winding and shielding
          PP2
          Copper wire braided copper tape winding and shielding

          Nine, cable specifications:

          model
          some
          Nominal cross section was,
          All the models
          3 + 3
          3 + 1
          1
          4,6,10,16,25,35,50,70,95,
          120150185240
          The main core of nominal section was
          Grounding wire core section was
          4
          1 (0.75)
          6
          1.5 (1)
          10
          2.5 (1.5)
          16, 25
          4 (2.5)
          35
          6
          50, 70
          10
          95
          16
          120, 150
          25
          185
          35
          240
          50 (35)

          Ten, basic cable specifications and structure parameters:

          Wire core * nominal section (was)
          Conductor structure
          (Root number * diameter)
          mm
          Maximum overall diameter (mm)
          BPVVPP2
          BPYJVPP2
          BPGGPP2
          3 * 4
          1/2.26
          13.5
          15.5
          3 * 6
          1/2.78
          14..0
          16.0
          3 * 10
          7/1.35
          19.0
          21.0
          3 * 16
          7/1.70
          22.0
          24.0
          3 * 25
          7/2.15
          25.0
          26.5
          3 * 35
          7/2.52
          26.0
          35.5
          3 * 50
          10/2.52
          28.5
          40.0
          3 * 70
          14/2.52
          31.5
          43.5
          3 * 95
          19/2.52
          36.5
          50.0
          3 * 120
          24/2.52
          40.0
          56.0
          3 * 150
          30/2.52
          45.0
          60.0
          3 * 185
          37/2.52
          47.0
          67.0
          3 * 4 + 3 * 0.75
          1/2.26
          14.5
          16.5
          3 * 6 + 3 * 1
          1/2.78
          15.0
          17.0
          The 10 + 3 * 3 * 2.5
          7/1.35
          20.8
          22.0
          16 + 3 * 3 * 2.5
          7/1.70
          23.0
          25.0
          25 + 3 * 3 * 4
          7/2.15
          28.0
          27.5
          35 + 3 * 3 * 6
          7/2.52
          32.0
          36.5
          50 + 3 * 3 * 10
          10/2.52
          37.0
          41.0
          70 + 3 * 3 * 10
          14/2.52
          41.6
          44.5
          95 + 3 * 3 * 16
          19/2.52
          47.0
          51.0
          120 + 3 * 3 * 25
          24/2.52
          50.1
          57.0
          150 + 3 * 3 * 25
          30/2.52
          52.0
          61.0
          185 + 3 * 3 * 35
          37/2.52
          58.5
          68.0

          11 technical data:
          1, according to DIN VDE fifth class soft stranded copper conductors.
          2 insulation, weather resistance and heat-resistant resin.
          3, soft shield.
          Along with the development of the frequency control drive technology, more and more high to the requirement of the variable frequency drive system, especially for the fast switch IG BT semiconductor modern frequency conversion technology, though it has high pulse frequency and more time only milliseconds, but they would have a positive magnetic field on the surrounding environment.In order to make the inverter work normally, not affected by electromagnetic interference, so the connection between the inverter and three phase ac motor cable requires has anti-jamming performance, low effective capacitance and low transfer impedance.